Saltar al contenido principal

Effects of higher portions of variable renewable energy in electricity power systems = Efectos en los sistemas eléctricos de potencia con el incremento de energías renovables variables o intermitentes

Registro bibliográfico

  • Título: Effects of higher portions of variable renewable energy in electricity power systems = Efectos en los sistemas eléctricos de potencia con el incremento de energías renovables variables o intermitentes
  • Autor: Ríos Echeverry, Andrés Mauricio
  • Publicación original: 2014
  • Descripción física: PDF
  • Nota general:
    • Worldwide electricity power systems are evolving from conventional/dispatchable sources to environmental friendly but Not-dispatchable renewable energy (RE) sources. This has effects on the dynamic of the system and on conventional and RE generators, electricity quality and energy cost. This research identifies the main effects of higher portions of Non-dispatchable RE based on a reference case. An MATLAB/EXCEL “ad-hoc” model has been developed. It simulates the Unit Commitment (UC) and Economic Dispatch (ED) with 10 conventional generators and one zero fuel cost RE generator (Non-dispatchable RE as “study-case” and Dispatchable RE “reference-case”).
      Results indicated that higher portions of Non-dispatchable RE had a swapping effect where base load units were displaced. Consequently, the system ran at lower cost-efficient point, the number of Start-ups and RE curtailment increased compared to the reference case. Furthermore, conventional generators running cost and system running cost followed the variable pattern of the Non-dispatchable RE source. Meanwhile, these costs were linked to the demand in the reference case. Ultimately, higher portions of Non-dispatchable RE made the system underperform compared to the reference case. Therefore, this incentive technology that lessen unwanted effects. Future studies shall focus on increasing the number of units and complexity of the system by using more powerful software.
  • Notas de reproducción original: Digitalización realizada por la Biblioteca Virtual del Banco de la República (Colombia)
  • Notas:
    • Resumen: Dispatchable source; Economic dispatch; Effects; Mixed electricity power system; Model; Non-disptchable source; Renewable energy; Unit commitment; Variability
    • © Derechos reservados del autor
    • Colfuturo
  • Forma/género: tesis
  • Idioma: inglés
  • Institución origen: Biblioteca Virtual del Banco de la República
  • Encabezamiento de materia:
Effects of higher portions of variable renewable energy in electricity power systems = Efectos en los sistemas eléctricos de potencia con el incremento de energías renovables variables o intermitentes | Biblioteca Virtual Miguel de Cervantes Ampliar imagen

Digitalización realizada por la Biblioteca Virtual del Banco de la República (Colombia)

Citar obra

Datos enlazados

RDF de esta obra

La Biblioteca Virtual Miguel de Cervantes publica su catálogo como datos abiertos a través del vocabulario Resource Description and Access (RDA) en data.cervantesvirtual.com